Quick answer: Nitrile and vinyl examination gloves are covered by ASTM D6319 and ASTM D5250, standards published by ASTM International. Polyisoprene is a synthetic rubber used in sterile surgical gloves, which are covered by ASTM D3577. AQL (acceptable quality limit) measures how strictly a batch is checked for holes; lower is stricter, and surgical gloves are held to a stricter AQL than examination gloves. In Canada, all medical gloves are Class II medical devices that need a Health Canada licence.
What is the difference between an examination glove and a surgical glove?
The standards answer this.
- ASTM D6319 (nitrile) covers nitrile rubber gloves "used in conducting medical examinations and diagnostic and therapeutic procedures." It provides for sterile or non-sterile gloves, packaged or in bulk.
- ASTM D5250 (vinyl) covers "poly(vinyl chloride) gloves used in conducting medical examinations and diagnostic and therapeutic procedures," and also gloves "used in handling contaminated medical material."
- ASTM D3577 (surgical) covers "packaged sterile rubber surgical gloves used in conducting surgical procedures," in natural rubber latex (Type 1) or synthetic rubber latex (Type 2).
Synthetic polyisoprene surgical gloves fall under the synthetic type. Ansell, for example, lists ASTM D3577 for its polyisoprene surgical glove.
Health Canada's glove guidance (now archived) lists the matching International Organization for Standardization (ISO) standards too: ISO 11193 for examination gloves and ISO 10282 for surgical gloves.
What does AQL mean?
AQL stands for acceptable quality limit (often called acceptable quality level). It comes from the sampling standard ISO 2859-1, which defines it as "the worst tolerable process average when a continuing series of lots is submitted for acceptance sampling."
In plain terms: a manufacturer tests a sample from each batch for holes. The AQL sets how many failures the sample may contain before the batch is rejected. As Ansell puts it, "The lower the AQL, the better the quality and less likelihood of defects."
Which AQL applies to which glove?
| Glove type | Standard | AQL for freedom from holes |
|---|---|---|
| Nitrile examination | ASTM D6319-19 | 2.5 |
| Latex examination | ASTM D3578-19 | 2.5 |
| Surgical (latex or synthetic) | ASTM D3577-19 | 1.5 |
| Examination (EU) | EN 455-1:2020 | 1.5 |
| Surgical (EU) | EN 455-1:2020 | 0.65 |
Source: Ansell's AQL summary. In the US, the Food and Drug Administration (FDA) sets the floor in regulation: "a 1.5 AQL to be the minimum level of quality acceptable for surgeons' gloves" and "a 2.5 AQL to be the minimum level of quality acceptable for patient examination gloves."
Some manufacturers test to a stricter AQL than the standard requires. Ansell, for instance, publishes 0.4 AQL for one of its polyisoprene surgical gloves. Check the product data sheet.
How do nitrile, vinyl and polyisoprene compare?
| Nitrile | Vinyl (PVC) | Polyisoprene | |
|---|---|---|---|
| Material | Synthetic nitrile rubber | Poly(vinyl chloride) | Synthetic polyisoprene rubber |
| Form in this article | Examination glove | Examination glove | Sterile surgical glove |
| ASTM standard | D6319 | D5250 | D3577 (Type 2, synthetic) |
| Natural rubber latex | No | No | No (synthetic; free from natural rubber latex proteins, per Ansell) |
| In-use barrier (one study) | Failed 1% to 3% after simulated use | Failed 12% to 61% after simulated use | Not tested in that study |
Are vinyl gloves as protective as nitrile?
One study suggests not, under stress. In 1999, Rego and Roley tested latex, nitrile and vinyl gloves in the American Journal of Infection Control. Straight from the box, there were no significant differences except one vinyl brand with a 12% failure rate. After manipulation intended to simulate use, "vinyl gloves failed 12% to 61% of the time," while "latex and nitrile performed significantly better, with failure rates of only 0% to 4% and 1% to 3%, respectively."
The study is older and products have changed since, so treat it as a signal rather than a verdict on today's brands. Your infection prevention policy decides which glove is used for which task.
What are polyisoprene surgical gloves?
Polyisoprene is a synthetic rubber, so it avoids natural rubber latex. Ansell describes its polyisoprene surgical glove as "free from natural rubber latex proteins," eliminating Type I latex allergy risks.
ASTM D3577 covers surgical gloves supplied packaged and sterile. The Medispo Premium Sterile Polyisoprene Surgical Gloves on Kleos Shop are powder-free, sized 5.5 to 9.5 and sold in boxes of 50 pairs. They are licensed by Health Canada under licence 108829, "Polyisoprene Surgical Gloves," Class II; catalogue numbers MPIG55 to MPIG95 appear under that licence in MDALL.
What does Health Canada require for medical gloves?
Health Canada's glove notice and its (now archived) glove guidance are direct:
- "In Canada, all medical gloves are Class II medical devices."
- Health Canada "licenses all disposable medical examination gloves imported and sold in Canada," "whether the gloves are made of latex, vinyl, synthetic polymer or nitrile, or are sterile or non-sterile."
- "You cannot import or sell a Class II medical device unless the manufacturer has a medical device licence from Health Canada."
- Non-medical gloves should not be presented as medical. Health Canada recommends labels such as "Industrial use only," "Not for medical use" or "Not a medical device."
So before buying, look for the word "examination," "surgical" or "medical" on the box, and check the licence in the Medical Devices Active Licence Listing (MDALL). Our MDALL guide shows how.
Questions clinics ask
What AQL should I look for in examination gloves?
ASTM D6319 nitrile and D3578 latex examination gloves are held to AQL 2.5 for holes. A lower number is stricter.
Are polyisoprene gloves latex-free?
They are made from synthetic polyisoprene, not natural rubber latex. Ansell describes its polyisoprene surgical glove as free from natural rubber latex proteins.
Do vinyl gloves meet a medical standard?
Yes, if they are made to one. ASTM D5250 covers vinyl gloves for medical examinations.
Are all medical gloves licensed in Canada?
Yes. Health Canada classes all medical gloves as Class II devices, which require a manufacturer's licence.
Is a lower AQL always better?
Lower means a stricter hole test on each batch, so fewer defects are tolerated.
Sources
- ASTM International. ASTM D6319-19(2023) Nitrile examination gloves. store.astm.org
- ASTM International. ASTM D5250-19(2023) Poly(vinyl chloride) gloves. store.astm.org
- ASTM International. ASTM D3577-19(2023) Rubber surgical gloves. store.astm.org
- Ansell. What is acceptable quality level and why it matters. ansell.com
- Ansell Canada. GAMMEX Non-Latex PI (polyisoprene). ansell.com
- US Code of Federal Regulations. 21 CFR 800.20, Patient examination gloves and surgeons' gloves; sample plans and test method for leakage defects. law.cornell.edu
- Rego A, Roley L. In-use barrier integrity of gloves: latex and nitrile superior to vinyl. Am J Infect Control. 1999;27:405-410.
- Health Canada. Important regulatory considerations for the supply of medical gloves during the COVID-19 outbreak (archived; modified 2024-01-03). canada.ca
- Health Canada. Notice: Medical gloves. canada.ca
- Health Canada. Medical Devices Active Licence Listing, licence 108829. health-products.canada.ca