Quick answer: 3M Tegaderm 1624W and 1626W are sterile, transparent film dressings that cover and protect a site, such as an IV (intravenous) catheter site. Mepitac is a non-sterile soft silicone tape for fixing tubes, cannulae and dressings, especially on fragile or sensitive skin. 3M Transpore 1527-1 is a transparent, perforated plastic tape for everyday securement on intact skin. They do different jobs, so a clinic that runs IV or procedure rooms may need all three.
What is the difference between a film dressing and a tape?
A film dressing covers. A tape holds.
Tegaderm Transparent Film Dressing is a dressing in its own right. Solventum (the company that now makes 3M health care products) describes it as a "waterproof, sterile barrier to external contaminants including liquids, bacteria and viruses," with a transparent film that allows "continuous visibility to the I.V. insertion site." Solventum notes that this rests on in vitro testing against viruses 27 nm in diameter or larger.
Mepitac and Transpore are tapes. They fix something else in place: a cannula, a line, a gauze pad or another dressing. Neither is a dressing.
How do the three compare?
| 3M Tegaderm 1624W / 1626W | Mepitac (298300) | 3M Transpore 1527-1 | |
|---|---|---|---|
| What it is | Transparent film dressing, Frame Style delivery | Soft silicone fixation tape (Safetac technology) | Transparent, perforated plastic surgical tape |
| Sterile | Yes | No | Not listed as sterile |
| Size | 1624W: 6 x 7 cm. 1626W: 10 x 12 cm (see note) | 2 cm x 3 m roll | 2.5 cm x 9.1 m roll |
| Adhesive | Hypoallergenic adhesive | Soft silicone | Acrylate (pressure sensitive) |
| Latex | Not made with natural rubber latex | No natural rubber latex, per Mölnlycke's 2021 technical sheet | Not made with natural rubber latex |
| Manufacturer's listed uses | IV catheter sites, superficial wounds, skin protection and more | Fixation of drains, tubes, probes, electrodes, IV cannulae and dressings | Blood draws, lightweight dressings, secondary securement of IV lines and non-critical tubes |
| Manufacturer's cautions | Follow the instructions for use | Not for life-supporting devices, arterial catheters or arterial cannulae. Adhesion may drop in humid conditions or on diaphoretic (sweating) patients | Ideal for intact skin. Do not stretch during application |
Note on size: Solventum's product page lists 1626W as 10 x 12 cm (4 x 4.75 in). One Solventum product guide prints 10 x 11.5 cm. If exact size matters for your protocol, check the box.
When is Tegaderm the right choice?
Choose a transparent film when you want to cover a site and still see it.
Solventum's suggested applications for Tegaderm 1624W and 1626W include covering and protecting IV catheter sites, superficial wounds such as minor abrasions, skin protection, and primarily closed clean surgical wounds.
In a clinic, these are treatment-room products. Kleos Shop supplies them for in-clinic use by your clinical team, applied and removed as part of the procedure.
For IV catheter sites, the US Centers for Disease Control and Prevention (CDC) guideline on intravascular catheter-related infections says to "use either sterile gauze or sterile, transparent, semipermeable dressing to cover the catheter site" (Category IA). The same guideline adds two conditions worth knowing:
- "If the patient is diaphoretic or if the site is bleeding or oozing, use gauze dressing until this is resolved" (Category II).
- "Replace catheter site dressing if the dressing becomes damp, loosened, or visibly soiled" (Category IB).
The two sizes suit different sites. The 6 x 7 cm 1624W covers a small site. The 10 x 12 cm 1626W covers a larger area.
When does a silicone tape like Mepitac make sense?
Choose Mepitac when the skin matters as much as the hold.
Mölnlycke designs Mepitac "for fixation of drains, tubes, probes, electrodes, IV cannulae and dressings," and says it "can be used under devices such as tubes or cannulae to protect skin." Its product sheet describes it as suitable for fragile and sensitive skin and for people who need tape applied and removed over the same area repeatedly. The tape can be lifted and re-applied.
Two cautions come from Mölnlycke:
- "Mepitac® is not intended for fixation of life supporting devices or for use on arterial catheters or cannulae."
- "The adhesion of Mepitac® may decrease when used in humid conditions such as incubators or for diaphoretic patients."
The 2013 consensus statement on medical adhesive-related skin injury (MARSI) supports the trade-off. It notes that "limited evidence suggests that these products are gentler than other types of adhesives," and also advises caution, because using silicone tapes for primary securement of critical tubes and devices "may result in suboptimal adherence or adhesion failure."
Where does Transpore fit?
Transpore is the everyday tape. Solventum lists it for "blood draws, lightweight dressings and secondary securement of IV lines and non-critical tubes." It has a straight, bi-directional tear that is easy to handle with gloves, and it is a plastic tape not made with natural rubber latex.
Solventum says Transpore is "ideal for intact skin" and suggests a barrier such as Cavilon No Sting Barrier Film for at-risk skin.
How do you reduce tape-related skin injury?
The MARSI consensus defines a medical adhesive-related skin injury as redness or another skin change (such as a blister, erosion or tear) that "persists 30 minutes or more after removal of the adhesive."
The consensus and the manufacturers agree on a few basics:
- Apply without tension. Solventum warns that "pulling or stretching during application may result in tension blisters."
- Remove low and slow. The consensus recommends removing adhesive "low and slow back over itself in the direction of hair growth," and notes that "rapid, vertical pulling has been shown to generate a higher peel force than slow removal."
- Match the adhesive to the skin. Solventum's taping guide says to "match strength of adhesive to clinical needs and skin condition." Mölnlycke positions Mepitac for fragile skin and repeated taping; Solventum positions Transpore for intact skin.
Follow your college's standards, each product's instructions for use and your medical director for any patient-specific decision.
Are these products licensed in Canada?
Tegaderm Transparent Film Dressing is a Class II device in Health Canada's Medical Devices Active Licence Listing (MDALL), licence 77881, and both 1624W and 1626W appear as device identifiers under that licence. See our step-by-step guide to checking a licence in MDALL.
Questions clinics ask
Is Tegaderm waterproof?
Yes. Solventum describes Tegaderm as a waterproof, sterile barrier.
Can I reposition Mepitac?
Mölnlycke says Mepitac can be lifted and re-applied if needed, which helps when a line or dressing needs adjusting during a procedure.
Is Transpore latex-free?
Solventum states Transpore is a plastic tape not made with natural rubber latex.
Is Mepitac sterile?
No. Mölnlycke's 2021 technical sheet (fiche technique) describes it as non-sterile, and the US device database lists it as not packaged sterile.
Which tape is gentlest on fragile skin?
Mölnlycke positions Mepitac for fragile and sensitive skin. The MARSI consensus says limited evidence suggests silicone adhesives are gentler, with a trade-off in holding power for some devices.
What is the difference between 1624W and 1626W?
Size and count. 1624W is 6 x 7 cm, 100 per box. 1626W is 10 x 12 cm, 50 per box.
Sources
- Solventum. 3M Tegaderm Transparent Film Dressing Frame Style, 1626W. solventum.com
- Solventum. 3M Tegaderm Transparent Film Dressing Frame Style, 1624W. solventum.com
- Solventum. 3M Tegaderm Transparent Film Dressings product guide (70-2013-1678-6, 2024).
- Solventum. 3M Transpore Surgical Tape 1527-1. solventum.com
- Mölnlycke Health Care Canada. Mepitac product sheet. prepcorporate.molnlycke.com
- Mölnlycke Health Care. Mepitac fiche technique (2021). molnlycke.com
- McNichol L, Lund C, Rosen T, Gray M. Medical adhesives and patient safety: state of the science consensus statements for the assessment, prevention, and treatment of adhesive-related skin injuries. J Wound Ostomy Continence Nurs. 2013;40(4):365-380. doi:10.1097/WON.0b013e3182995516
- US Centers for Disease Control and Prevention. Guidelines for the Prevention of Intravascular Catheter-Related Infections, 2011 (updated 2017). cdc.gov
- Health Canada. Medical Devices Active Licence Listing, licence 77881. health-products.canada.ca
- US National Library of Medicine. AccessGUDID: Mepitac 2 cm x 3 m. accessgudid.nlm.nih.gov