Quick answer: An insulin syringe is a small plastic syringe, usually with a fixed needle, and a scale printed in units of U-100 insulin. On a U-100 scale, 100 units equal 1 mL, so each unit equals 0.01 mL. When the needle is fixed, very little liquid stays behind after the plunger is pushed home, which matters when you draw small volumes.
What is an insulin syringe?
An insulin syringe is a single-use syringe made for one job: drawing up and injecting insulin. The International Organization for Standardization (ISO) standard for these syringes, ISO 8537:2016, covers "empty, sterile, single-use syringes, with or without needles," made of plastic and intended solely for insulin injection, filled by the user and used immediately.
The labelled intended use matters. Sol-Millennium describes its Sol-M Standard Insulin Syringe as "used to inject insulin into the body." Distributor literature for U-100 syringes states they are "intended for use with U-100 insulin only." Any other use of the syringe is a clinical decision. Follow your college's standards, the product's instructions for use and your medical director.
What do the U-100 markings mean in millilitres?
U-100 insulin contains 100 units per mL. A U-100 syringe scale is printed to match, so the numbers on the barrel are also a volume scale.
| Barrel size | Holds (U-100 units) | Volume per unit |
|---|---|---|
| 0.3 mL | 30 units | 0.01 mL |
| 0.5 mL | 50 units | 0.01 mL |
| 1 mL | 100 units | 0.01 mL |
One point is easy to miss in aesthetic practice. The "units" printed on an insulin syringe are units of U-100 insulin. With any other liquid, they are only a volume marker (0.01 mL each). They do not describe the units of any other product.
Scale matching also matters within insulin itself. Lilly's US medical information page states that its concentrated U-500 insulin must be used with the dedicated BD U-500 syringe, where "each marking ... represents 5 units of insulin," to avoid administration errors. The lesson for any clinic: the scale on the barrel only means what it was designed to mean.
Why does barrel size change how easy the scale is to read?
In a smaller barrel, each unit takes up more length on the scale. HealthLinkBC notes that "the measuring lines on the barrel of small syringes are farther apart and easier to see."
So if you routinely draw small volumes, a 0.3 mL barrel gives you a longer, more readable scale than a 1 mL barrel. Line spacing, labelling and how many units each printed line represents differ by barrel size and brand, so check the barrel before you add a new model to your protocol.
What is dead space, and why does it matter?
"Dead space" is the liquid left inside the syringe hub and needle after the plunger is fully depressed. A 2018 measurement study by Zule and colleagues put it simply: "all needle and syringe combinations retain some residual fluid in the needle itself."
How much depends on design:
- Fixed-needle syringes (insulin-type, needle permanently attached): mean dead space of 3.0 µL (microlitres) in the Zule study.
- Standard (high dead space) syringes with standard detachable needles: mean of 98.9 µL in the same study.
- A 2021 measurement study of vaccine supplies (Smith and colleagues) estimated that one-inch needles on separate syringes leave "approximately 0.05 mL of dead space per vaccine."
For a clinic, dead space is product you paid for that never leaves the syringe. Sol-Millennium states its low dead space design "results in 80% less medication waste compared to the ISO standard for conventional insulin syringes." That figure is the manufacturer's claim.
Which gauge and needle length should a clinic stock?
Insulin syringes come with fine, short, fixed needles. Sol-Millennium's U-100 range runs from 27G to 31G, with needle lengths from 6 mm to 16 mm (6, 8, 12.5 and 16 mm), in 0.3 mL, 0.5 mL and 1 mL barrels. BD lists 1 mL, 0.5 mL and 0.3 mL capacities with 6 mm, 8 mm and 12.7 mm needles.
A higher gauge number means a thinner needle. For example, published manufacturer specifications give a 30G needle an outside diameter of about 0.30 mm and a 27G needle about 0.40 mm. See our guide to gauge, length and tip design for the full table.
The choice of gauge and length for any procedure is a clinical decision. This article covers the device only.
How do the Sol-M syringes on Kleos Shop compare?
| Sol-M 0.3 mL, 31G x 6 mm | Sol-M 0.3 mL, 31G x 8 mm | Sol-M 1 mL, 31G x 6 mm | |
|---|---|---|---|
| Reference | 163311564B | 1633151B | 161311564B |
| Scale | U-100 | U-100 | U-100 |
| Needle | Fixed, tri-bevel, silicone lubricated | Fixed, tri-bevel, silicone lubricated | Fixed, tri-bevel, silicone lubricated |
| Sterile, single use | Yes | Yes | Yes |
| Box | 100 syringes | 100 syringes | 100 syringes |
| Health Canada licence | 72663 (Class II) | 72663 (Class II) | 72663 (Class II) |
All three reference numbers appear under Health Canada licence 72663, held by Sol-Millennium Medical, Inc., in the Medical Devices Active Licence Listing (MDALL).
Quick buying checklist
- Scale matches the product you will draw (U-100 scale for U-100 insulin).
- Barrel size fits the volumes you draw most often.
- Fixed needle if low dead space matters to you.
- Sterile, single use, and latex status on the label.
- Health Canada licence number confirmed in MDALL.
Questions clinics ask
How many millilitres is one unit on an insulin syringe?
On a U-100 scale, one unit is 0.01 mL, because 100 units equal 1 mL. Check how many units each printed line represents on the barrel you stock.
Do the units on an insulin syringe match units of other products?
No. The printed units are U-100 insulin units. With any other liquid they act only as a 0.01 mL volume scale.
Why do fixed-needle syringes waste less?
There is less space in the hub and needle for liquid to stay behind. In one measurement study, fixed-needle syringes retained a mean of 3.0 µL versus 98.9 µL for standard syringes with standard detachable needles.
Is a 0.3 mL syringe easier to read than a 1 mL syringe?
Usually, yes. The scale is spread over more length, so the lines sit farther apart.
Can insulin syringes be reused?
No. ISO 8537 covers single-use syringes, and Sol-M syringes are labelled single use.
Are Sol-M insulin syringes licensed in Canada?
Yes. Their reference numbers are listed under Health Canada licence 72663 (Class II).
Sources
- Sol-Millennium Medical. Sol-M Standard Insulin Syringe, U100, sell sheet NACA-DC-463-0425.
- International Organization for Standardization. ISO 8537:2016 Sterile single-use syringes, with or without needle, for insulin. iso.org
- HealthLinkBC. Insulin syringes (current as of March 1, 2023). healthlinkbc.ca
- McKesson Medical-Surgical. McKesson insulin syringe product sheet. imgcdn.mckesson.com
- Eli Lilly. Which syringe can be used with Humulin R U-500? (reviewed April 22, 2022). medical.lilly.com
- Zule WA, Pande PG, Otiashvili D, et al. Options for reducing HIV transmission related to the dead space in needles and syringes. Harm Reduct J. 2018;15:3. doi:10.1186/s12954-017-0207-5
- Smith DM, Weiss SL, White KM. Quantification of COVID-19 vaccine needle and syringe dead space volumes. Cureus. 2021;13(10):e18969. doi:10.7759/cureus.18969
- BD. BD Insulin Syringes with BD Ultra-Fine Needle. bd.com
- Terumo Europe. K-Pack II needles, size table. terumo-europe.com
- Health Canada. Medical Devices Active Licence Listing, licence 72663. health-products.canada.ca